Skip to Content

ZC 3-faasiline Pooljuhtrelee (SSR) 3X75A/24-520VAC/Juhtimispinge 24-255VAC/DC

Kogege täpset juhtimist ja usaldusväärset toimimist meie SGT8678500 kolmefaasilise SSR SYNCH-iga. Tahkisrelee on loodud vastupidavust silmas pidades, pakub tugevat 3x75A türistori hinnangut, tagades tõhusa toimimise laias pingevahes 24-520VAC. Ideaalne mitmesugusteks rakendusteks, sealhulgas kütteelemendid, mootorid ja erinevad valgustussüsteemid. Vastab CE, EAC, UKCA ja UL standarditele, tagades töökindluse tööstuskeskkondades.
Specifications
Product Name: SGT8678500 Three-Phase SSR SYNCH
Type: Three-phase SSR - Zero cross - with output protection
Thyristor Rating: 3x75A
Max. Switching Current (A):
3x16A AC-3 @40°C
3x54A AC-1 @40°C
Type of Mounting: To screw
Number of Poles: 3- Three-phase
Function: AC on/off Zero-Cross
Switching Voltage Rate: 24-520VAC
Control Voltage Rate: 24-255VAC/DC

Standards:
CE
EAC
UKCA
UL (cURus)

Features:
Three-phase SSR SYNCH. 3X75A/24-520VAC/CTRL 24-255VAC/DC
Type of Relay (AC or DC): AC
Series: SGT 2G
Output Protection Type: RC, VDR
Heatsink Included: NO
Terminals (Power): Screws
Housing Type: Standard

Application:
(AC-1 / LC A) Heating elements
(AC-3 / LC B) Motors
(AC-5a / LC C) Discharge lamps
(AC-5a / LC D) Incandescent light bulbs and infrared lamps
(AC-5b/DC-6) LEDs
(AC-6b / LC F) Capacitors
(AC-14/AC-15/DC-13) Electrovalves and electromagnets
(AC-14/AC-15/DC-13/DC-14) Contactors
320,71 € 320,71 € (ilma km-ta)

  • Min thyristor rating per phase (A)
  • Relay application
  • Relay control voltage nominal
  • Relay enclosure
  • Relay function
  • Relay heatsink
  • Relay max switching current per phase 40c a
  • Relay number of poles
  • Relay output protection type
  • Relay standards
  • Relay switching voltage
  • Relay terminals
  • Relay type AC DC
  • Relay type of mounting
  • Weight
Müügitingimused
Hinnad ei sisalda käibemaksu.

Manufacturer Part Number: SGT8678500
Tootekood: EE-100-188-025

Spetsifikatsioon

Relay application Ac 14 ac 15 dc 13 cc 14 contactors, Ac 14 ac 15 dc 13 electrovalves and electromagnets, Ac 3 lc b motors, Ac 5a lc c discharge lamps, Ac 5a lc d incandescent light bulbs and infrared lamps, Ac 5b dc 6 leds, Ac 6b lc f capacitors, Ac1 lca heating elements
Relay control voltage nominal 230 VAC, 24 VAC, 24 VDC
Relay output protection type Rc, VDR
Relay standards CE, EAC, UKCA, UL cURus
Relay switching voltage 110/120 VAC, 230 VAC, 400 VAC, 480 VAC
Min thyristor rating per phase (A) 70 79 (Min thyristor rating per phase (A))
Relay enclosure Standard (Relay enclosure)
Relay function Ac on off zero crossing
Relay heatsink No (Relay heatsink)
Relay max switching current per phase 40c a 50 59 (Relay max switching current per phase 40c a)
Relay number of poles Three phase
Relay terminals Screws
Relay type AC DC AC
Relay type of mounting Screw (Relay type of mounting)
Weight 0.3201 kg