Fluke T5-600/62MAX+/1AC II IR-termomeeter, elektritestri ja pingedetektori komplekt
See komplekt on mõeldud selleks, et aidata elektrikel ja HVAC-tehnikutel probleeme kiiremini lahendada. Testige kõigepealt ülekuumenenud elektriseadmeid IR-termomeetri abil; seejärel kasutage elektrilisi testimisvahendeid, et probleemi kohta rohkem teada saada.
Fluke T5-600/62MAX+/1AC II IR Thermometer, Electrical Tester and Voltage Detector Kit
Fluke T5-600 Voltage, Continuity and Current Tester
Specifications
Jaw opening12.9 mm (0.5 in)
Max wire size1/0 THHN cable
Current range AC rms0 to 100.0 A
Accuracy AC current (50/60 Hz)3% ± 3 counts
AC ResponseAveraging
Voltage range AC0 to 600 V
Accuracy AC voltage1.5% ± 2 counts
Voltage range DC0 to 600 V
Accuracy DC voltage1% ± 1 count
Resistance range0 to 1000 Ω
Continuity beeper thresholdOn at < 25 Ω, off at > 400 Ω
Volts indicator LED thresholdGuaranteed on by 30 V AC
Environmental Specifications
Operating temperature-10°C to 50°C
Storage temperature-30°C to 60°C
Humidity (without condensation)0% to 95% (5°C to 30°C); 0% to 75% (30°C to 40°C);
0% to 45% (40°C to 50°C)
Dust/water resistanceYes
Operating altitude2000 meters max
Temperature coefficient0.1 x (specified accuracy)/°C (< 18°C or > 28°C)
Safety Specifications
Measurement CategoryIEC 61010-2-032, IEC61010-2-033: CAT III 600 V, 100 A ac
Agency approvalsCSA, TUV
Maximum voltage600 V between any terminal and earth ground
Mechanical and General Specifications
Size30.5 x 51 x 203 mm
Weight300 g
WarrantyTwo-years
Battery life200 hour zinc chloride, 400 hour alkaline
Battery type2 x AA
Low battery indicatorYes
Current sensor opening12.9 mm
Calibration cycle1 year
Test leadsTypeHeavy duty, flexible leads rated for 1000 V use.
Field replaceable leads terminate in male shrouded banana plugs
ProbesOne red, one black.
Detachable Slim-Reach™ probe tips
StylesTP1 Slim Reach™ test brobes
Safety Specifications
SafetyCAT IV 600 V, CAT III, 1000 V
Maximum voltage1000 V AC rms from earth to ground, in compliance with EN61010
Fluke 62 MAX+ Infrared Thermometer
Specifications
Temperature range-30°C to 650°C (-22°F to 1202°F)
Accuracy±1.0°C or ±1.0% of reading, whichever is greater
-10°C to 0°C: ±2.0
-30°C to -10°C: ±3.0
Response time (95%)< 300 ms (95% of reading)
Spectral response8 to 14 microns
Emissivity0.10 to 1.00
Optical resolution12:1 (calculated at 90% energy)
Display resolution0.1°C (0.2°F)
Repeatability of readings±0.5% of reading or < ±0.5°C (1°F), whichever is greater
PowerAA battery
Battery life8 hours with laser and backlight on
Physical Specifications
Weight255 g (8.99 oz)
Size175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature0°C to 50°C (32°F to 122°F)
Storage temperature-20°C to 60°C (-4°F to 140°F), (without battery)
Operating humidity10% to 90% RH non-condensing at 30°C (86°F)
Operating altitude2000 meters above mean sea level
Storage altitude12,000 meters above mean sea level
IP ratingIP 54 per IEC 60529
Drop test3 meters
Vibration and shockIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMCEN 61326-1:2006 EN 61326-2:2006
Standards and agency approvalComplianceEN/IEC 61010-1: 2001
Laser safetyFDA and EN 60825-1 Class II