Protocol conversion between Modbus RTU/ASCII/TCP, IEC 60870-5-101, and IEC 60870-5-104
Supports IEC 60870-5-101 master/slave (balanced/unbalanced)
Supports IEC 60870-5-104 client/server
Supports Modbus RTU/ASCII/TCP master/client and slave/server
Effortless configuration via web-based wizard
Status monitoring and fault protection for easy maintenance
Embedded traffic monitoring/diagnostic information for easy troubleshooting
microSD card for configuration backup/duplication and event logs
Built-in Ethernet cascading for easy wiring
Redundant dual DC power inputs and relay output
-40 to 75°C wide operating temperature models available
Serial port with 2 kV isolation protection
Security features based on IEC 62443,
Introduction
The MGate 5114 is an industrial Ethernet gateway with 2 Ethernet ports and 1 RS-232/422/485 serial port for Modbus RTU/ASCII/TCP, IEC 60870-5-101, and IEC 60870-5-104 network communications. By integrating commonly used power protocols, the MGate 5114 provides the flexibility needed to fulfill the various conditions that arise with field devices that use different communications protocols to connect to a power SCADA system. To integrate Modbus or IEC 60870-5-101 devices onto an IEC 60870-5-104 network, use the MGate 5114 as a Modbus master/client or IEC 60870-5-101 master to collect data and exchange data with IEC 60870-5-104 systems.
Easy Configuration via Web Console
The MGate 5114 Series comes with an illustrated Quick Setup guide designed to make configuration easy. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps.
Modbus RTU/ASCII/TCP Protocol Traffic Monitor
MGate 5114 Series gateways support Modbus RTU/ASCII/TCP, IEC 60870-5-101, and IEC 60870-5-104 Protocol Traffic Monitor for easy troubleshooting, especially during the installation stage. It is worth mentioning that traffic logs can be viewed in the popular troubleshooting tool, Wireshark. With this feature, you can easily analyze traffic to determine the root cause of a problem.
Maintenance Functions
MGate 5114 gateways support a system log function that records events in the MGate; users can easily review log data remotely through the web console. The gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PSCADA system when a device gets disconnected or does not respond, in which case the PSCADA system gets the status of each end device and then issues alarms to notify operators.
10/100BaseT(X) Ports (RJ45 connector)
2
Auto MDI/MDI-X connection
Magnetic Isolation Protection
Industrial Protocols
Modbus TCP Client (Master), Modbus TCP Server (Slave), IEC 60870-5-104 Client, IEC 60870-5-104 Server
Configuration Options
Web Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console
Management
ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, SSH, UDP, NTP Client
MIB
Time Management
Console Port
RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
No. of Ports
Connector
Serial Standards
Baudrate
Data Bits
Parity
Even, Mark, None, Odd, Space
Stop Bits
Flow Control
RTS Toggle (RS-232 only), RTS/CTS
RS-485 Data Direction Control
ADDC® (automatic data direction control)
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
Terminator for RS-485
Isolation
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
RS-485-2w
RS-485-4w
Industrial Protocols
Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave, IEC 60870-5-101 Master (Balanced/Unbalanced), IEC 60870-5-101 Slave (Balanced/Unbalanced)
Configuration Options
Mode
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Commands
Mode
Client (Master), Server (Slave)
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Client Connections
Max. No. of Server Connections
Max. No. of Commands
Mode
Max. No. of Client Connections
Max. No. of Server Connections
Max. No. of Information Objects
Mode
Master (Balanced/Unbalanced)
Slave (Balanced/Unbalanced)
Max. No. of Master Connections
Max. No. of Slave Connections
1 (Balanced), 31 (Unbalanced)
Max. No. of Information Objects
microSD Slot
Up to 32 GB (SD 2.0 compatible)
Input Voltage
Input Current
Power Connector
Screw-fastened Euroblock terminal
Contact Current Rating
Resistive load: 2 A @ 30 VDC
Housing
IP Rating
Dimensions
36 x 105 x 140 mm (1.42 x 4.14 x 5.51 in)
Weight
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Operating Temperature
MGate 5114: 0 to 60°C (32 to 140°F)
MGate 5114-T: -40 to 75°C (-40 to 167°F)
Safety
EMC
EMI
CISPR 32, FCC Part 15B Class B
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
Hazardous Locations
ATEX, Class I Division 2, IECEx Class 1 Division 2, ATEX, and IECEx certifications are underway. Please contact a Moxa sales representative for details.
Freefall
Shock
Vibration
IEC 60068-2-6, IEC 60068-2-64