The Fluke 3000 FC HVAC System lets you work on electrical panels faster, safer, easier with remote current and temperature modules
Connect your FC AC Wireless Current Clamp Module to your test point, and view the results up to 20 meters away on the FC Wireless Digital Multimeter. Plus, you can connect the t3000 FC Wireless K-Type wireless temperature module and view remote temperature measurements.
You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect™ modules as a system for multiple measurements.
From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the Fluke Connect remote modules captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. Fluke Connect wireless test tools also offer increased safety by letting you view readings in a separate location from the test point.
Now you can take readings on moving machinery, with only the measurement module in harm’s way.
The Fluke 3000 FC HVAC System provides measurement of all common electrical parameters
The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting:
AC and DC voltage measurements to 1000V
AC and DC current with 0.01 mA resolution
Continuity, resistance, diode test, capacitance and frequency measurements
MIN/MAX recording
CAT III 1000 V, Cat IV 600 V; IP54
Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:
True-RMS AC clamp meter
Measure up to 400 A AC
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
Inrush function
With the Fluke t3000 FC Wireless K-Type Temperature Module you can:
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
Fluke 3000 FC HVAC System
Includes:
Fluke 3000 FC Series Wireless Multimeter
Fluke a3000 FC Wireless AC Current Clamp Module
Fluke t3000 Thermocouple Thermometer
TL175 Test Leads
AC175 Alligator Clips
80PK-1 K-Type Bead Thermocouple
Magnetic hanging strap
Fluke 3000 FC Series Wireless Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications
AC Voltage
Range 1ResolutionAccuracy 2 3 4
45 Hz to 500 Hz500 Hz to 1 kHz
600.0 mV0.1 mV1.0 % + 32.0 % + 3
6.000 V0.001 V
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
1 All AC voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
4 Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
FunctionRangeResolutionAccuracy
mV600.0 mV0.1 mV0.09 % + 2
V6.000 V0.001 V0.09 % + 2
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V0.15 % + 2
?600 Ω1 ΩMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
?600.0 Ω0.1 Ω0.5 % + 2
6.000 kΩ0.001 kΩ0.5 % + 1
60.00 kΩ0.01 kΩ
60.00 kΩ0.1 kΩ
600.0 kΩ0.001 MΩ
50.00 MΩ0.01 MΩ1.5 % + 3
Diode test2.000 V0.001 V1 % + 2
µF1000 nF1 nF1.2 % + 2
10.00 μF0.01 μF
100.0 μF0.1 μF
9999 μF11 μF10 % typical
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
FunctionRange 1ResolutionAccuracy
mA AC
(45 Hz to 1 kHz)60.00 mA0.01 mA1.5 % + 3
400.0 mA 30.1 mA
mA DC 260.00 mA0.01 mA0.5 % + 3
400.0 mA 30.1 mA
1 All AC current ranges are specified from 5 % of range to 100 % of range.
2 Input burden voltage (typical): 400 mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload.
Frequency
RangeResolutionAccuracy 1
99.99 Hz0.01 Hz0.1 % + 1
999.9 Hz0.1 Hz
9.999 kHz0.001 kHz
99.99 kHz0.01 kHz
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
FunctionOverload
protectionInput impedance
(nominal)Common mode rejection ratio (1 kΩ unbalance)Normal mode rejection
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scale voltageTypical short circuit current
To 6 MΩ50 MΩ
1100 V RMS< 2.7 V DC< 0.7 V DC< 0.9 V DC< 350 mA
1100 V RMS< 2.7 V DC2.000 V DC< 1.1 mA
mA Function
Overload ProtectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
TemperatureOperating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative humidity0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
AltitudeOperating: 2,000 m
Storage: 12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RFEN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety complianceANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution degree2
Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm
(1.87 in x 3.68 in x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Note: Not compatible with Fluke CNX test tools
Fluke a3000 FC Wireless AC Current Clamp Module
Specifications
Range0.5 A to 400.0 A
Resolution0.1 A
Accuracy400.0 A: 2 % ± 5 digits (10 Hz to 100 Hz), 2.5 % ± 5 digits (100 Hz to 500 Hz)
InrushMax displayed reading: 999.9A
Crest factor (50 Hz/60 Hz)3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 % for C.F. > 2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Temperature coefficientAdd 0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C)
Operating humidity90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
AltitudeOperating: 2,000 m
Storage: 12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2
Safety ratingCAT III 600 V
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP30
Pollution degree2
Jaw opening34 mm (1.33 in)
Size (HxWxD)20.3 cm x 7.49 cm x 3.55 cm (8 in x 2.95 in x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years
Note: Not compatible with Fluke CNX test tools
Fluke t3000 FC Wireless K-Type Temperature Module
General Specifications
Range K-Type-200 °C to 1372 °C
Resolution0.1 °C
Accuracy± [0.5 % + 0.3 °C] counts
Input terminalsK-type mini
LCD w/backlight3 ½ digits
Log rate/interval1 sec minimum/adjustable by PC
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Temperature coefficient0.01 % of reading +0.03 °C per °C
Temperature scaleITS-90
Operating humidity90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
AltitudeOperating: 2,000 m
Storage: 12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, CAT I, 3rd edition Pollution Degree 2
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Size (HxWxD)16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years
Note: Not compatible with Fluke CNX test tools