Skip to Content

Fluke, FLK-393FC-PVLEAD, Ampertangid, ja, MC4, testijuhid, komplekt

  • Mõõtke ohutult CAT III 1500 V nimivõimsusega klemm-mõõturiga
  • Õhuke lõuend, mis võimaldab juurdepääsu kaablitele tihedalt täidetud ühenduskarpides
  • Tugev IP54-klassiga välistingimustes kasutamiseks ja päikesepaneelide jaoks
  • Töötage tõhusalt alalisvoolu mõõtmise, helipolaarsuse ja visuaalse järjepidevuse abil
  • Päikesepaneelide testijuhikud on mõeldud kasutamiseks päikesepaneelide klemm-mõõturitega, mis sobivad 4 mm banaani pistikute ja nimivõimsusega CAT III 1000 V / CAT IV 600 V
Specifications: Fluke 393 FC CAT III 1500 V True-rms Solar Clamp Meter

General
Maximum voltage between any Terminal and Earth Ground
AC1000 V
DC1500 V
Batteries2 AA IEC LR6 alkaline
DisplayDual display with backlight
Automatic Power Off20 minutes
Electrical
Accuracy
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature CoefficientsAdd 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC Current: Jaw
Range999.9 A
Resolution0.1 A
Accuracy2 % + 5 digits (10 Hz to 100 Hz)
2.5 % + 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz)2.5 @600.0 A
3.0 @500.0 A
1.42 @999.9 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range999.9 A
2500 A
Resolution0.1 A (≤999.9 A)
1 A (≤2500 A)
Accuracy3 % RD + 5 digits (10 Hz to 500 Hz)
Crest Factor (50/60Hz)2.5 @1400 A
3.0 @1100 A
1.42@2500 A
Add 2 % for C.F. >2
Position Sensitivity
NEC symbol
Distance from Optimumi2500-10 Flexi2500-18 FlexError
A0.5 in (12.7 mm)1.4 in (35.6 mm)±0.5 %
B0.8 in (20.3 mm)2.0 in (50.8 mm)±1.0 %
C1.4 in (35.6 mm)2.5 in (63.5 mm)±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range999.9 A
Resolution0.1 A
Accuracy2 % RD + 5 digits[1]
[1] When using the ZERO (B) function to compensate for offsets.
AC Voltage
Range600.0 V
1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1 % RD + 5 digits (20 Hz to 500 Hz)
DC Voltage
Range600.0 V
1500 V
Resolution0.1 V (≤600.0 V)
1 V (≤1500 V)
Accuracy1 % RD + 5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1 % RD + 5 digits
Amps Frequency: Jaw
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % RD + 5 digits
Trigger Level5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Amps Frequency: Flexible Current Probe
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % RD + 5 digits
Trigger Level5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage Frequency
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % RD + 5 digits
Trigger Level5 Hz to 20 Hz, ≥5 V
20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC Power
Range600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
Resolution0.1 kVA
1 kVA
Accuracy2 % RD + 2.0 kVA
2 % RD + 20 kVA
Resistance
Range600.0 Ω
6000 Ω
60.00 kΩ
Resolution0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
0.01 kΩ (≤60.00 kΩ)
Accuracy1 % RD + 5 digits
Capacitance
Range100.0 μF
1000 μF
Resolution0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy1 % RD + 5 digits
Inrush Trigger Level5 A
Mechanical
Size (L x W x H)281 mm x 84 mm x 49 mm
Weight (with batteries)520 g
Jaw Opening34 mm
Flexible Current Probe Diameter7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)1.8 m
Environmental
Operating Temperature-10 °C to 50 °C
Storage Temperature-40 °C to 60 °C
Operating HumidityNon condensing (<10°C)
≤90 % RH (at 10 °C to 30 °C)
≤75 % RH (at 30 °C to 40 °C)
≤45 % RH (at 40 °C to 50 °C)
Operating Altitude2000 m
Storage Altitude12 000 m
Ingress Protection (IP) RatingIEC 60529: IP54 non-operating
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety
GeneralIEC 61010-1, Pollution Degree 2
MeasurementIEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless Radio
Radio frequency certificationFCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless Radio Frequency Range2400 MHz to 2483.5 MHz
Output Power<100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address:
www.fluke.com/en-us/declaration-of-conformity


Specifications: Pomona PVLEAD1 and PVLEAD3 Solar PV Clamp Test Lead Set

PVLEAD1PVLEAD3
Solar PV Connector to 4mm Test Lead SetSolar PV Clamp Test Lead Set
ContactBrass, Nickel PlatedBrass, Nickel Plated
Length60”36”, 12”
VoltageCAT III 1000V,CAT III 1000V,
CAT IV 600VCAT IV 600V
Current20 amp20 amp
StandardsIEC 61010-031IEC 61010-031
882,00 € 882,00 € (ilma km-ta)


Manufacturer Part Number: FLK-393FC-PVLEAD
Tootekood: EE-100-176-096