Fluke I2000-FLEX
Omadused
Kolm mõõtepiirkonda: 20 A, 200 A ja 2000 A, 100 mV/A, 10 mV/A ja 1 mV/A väljund
Ideaalne voolu mõõtmiseks paksudel ja raskesti ligipääsetavatel juhtidel vooluahelat katkestamata
Maksimaalne juhi läbimõõt 7" (178 mm)
CAT III 600 V ohutusklass
Fluke I2000-FLEX Specifications
Current Ranges20 A, 200 A, 2000 A ACRMS
Output Sensitivity (AC-Coupled)100 mV, 10 mV, 1 mV per A
Load Impedance100 kΩ minimum
Accuracy (at 25°C)±1% of range (45 to 65 Hz)
Linearity (10 to 100% of range)±0.2% of reading
Noise8 mV ac rms (30 A), 2 mV ac rms (300 A, 3000 A)
Frequency Range10 Hz to 20 kHz (-3 dB)
Phase Error< ±1° (45 to 65 Hz), : ±10° (at 20 kHz)
Position Sensitivity (with cable >25 mm from the coupling)±2% of range
External Field (with cable >200 mm from the head)±1% of range
Power Supply2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
Temperature Coefficient±0.08% of reading per °C
Working Voltage600 V ac rms or dc
Head CableLength (double insulated): 24" (610 mm)
Diameter: 0.56" (14.3 mm)
Head Bend Radius1.5" (38.1 mm)
Cable Length (head to electronics)6.56' (2 m)
Output ConnectionBNC with BNC to Banana adapter included
Operating Temperature Range32 to 158°F (0 to 70°C) (head and electronics)
Storage Temperature Range-40 to 221°F (-40 to 105°C) (head)
-4 to 185°F (-20 to 85°C) (electronics)
Operating Humidity15 to 85% (non-condensing)
Weight6.34 oz (180 g) (head), 6.70 oz (190 g) (electronics)
Safety StandardsEN 61010-1: 2001
EN 61010-2-032: 2002
EN 61010-031: 2002
600 Vrms, Category III, Pollution Degree 2
EMC StandardsEN 61326: 1998 +A1, A2, & A3