AC WITHSTANDING |
|||
Output-Voltage Range |
0.100kV~ 5.000kV ac |
||
Output-Voltage Resolution |
2V/step |
||
Output-Voltage Accuracy |
± (1% of setting +5V) [no load] |
||
Maximum Rated Load |
200 VA (5kV/40mA) |
||
Maximum Rated Current |
40mA (0.5kV < V ? 5kV) 10mA (0.1kV ? V? 0.5kV) |
||
Output-Voltage Waveform |
Sine wave |
||
Output-Voltage Frequency |
50 Hz / 60 Hz selectable |
||
Voltage regulation |
± (1% of reading +5V) [full load → no load] |
||
Voltmeter Accuracy |
± (1% of reading+ 5V) |
||
Current Measurement Range |
0.001mA~040.0mA |
||
Current Best Resolution |
0.001mA / 0.01mA / 0.1mA |
||
AC Current Measurement Accuracy |
±(1.5% of reading +30 counts) when HISET < 1.00mA ±(1.5% of reading +3 counts) when HISET ? 1.00mA |
||
Window Comparator Method |
Yes |
||
ARC Detect |
Yes |
||
RAMP (Ramp-Up Time) |
0.1~999.9s |
||
TIMER (Test Time)* |
OFF, 0.5s~999.9s |
||
GND |
ON/OFF |
||
DC WITHSTANDING |
|||
Output-Voltage Range |
0.100kV~ 6.000kV dc |
||
Output-Voltage Resolution |
2V/step |
||
Output-Voltage Accuracy |
± (1% of setting +5V) [no load] |
||
Maximum Rated Load |
50W (5kV/10mA) |
||
Maximum Rated Current |
10mA (0.5kV < V ? 6kV) 2mA (0.1kV ? V? 0.5kV) |
||
Voltage regulation |
± (1% of reading +5V) [full load → no load] |
||
Voltmeter Accuracy |
± (1% of reading+ 5V) |
||
Current Measurement Range |
0.001mA~010.0mA |
||
Current Best Resolution |
0.001mA / 0.01mA / 0.1mA |
||
DC Current Measurement Accuracy |
±(1.5% of reading +30 counts) when HISET < 1.00mA ±(1.5% of reading +3 counts) when HISET ? 1.00mA |
||
Window Comparator Method |
Yes |
||
ARC Detect |
Yes |
||
RAMP (Ramp-Up Time) |
0.1~999.9s |
||
TIMER (Test Time)* |
OFF, 0.5s~999.9s |
||
GND |
ON/OFF |
||
INSULATION RESISITANCE |
|||
Output-Voltage |
50V~1000V dc |
||
Output-Voltage Resolution |
50V/step |
||
Output-Voltage Accuracy |
± (1% of setting +5V) [no load] |
||
Resistance Measurement Range |
1 Mohm~ 9500 Mohm |
||
|
Test voltage |
Measurable Range |
Accuracy |
|
50V?V?450V |
1 Mohm~ 50 Mohm 51 Mohm~ 2000 Mohm |
±(5% of reading +1 count) ±(10% of reading +1 counts) |
|
500V?V?1000V |
1M ohm~ 500 Mohm 501 Mohm~ 9500 Mohm |
±(5% of reading +1 count) ±(10% of reading +1 count) |
Window Comparator Method |
Yes |
||
Output Impedance |
600 kohm |
||
RAMP (Ramp-Up Time) |
0.1~999.9s |
||
TIMER (Test Time) |
1s~999.9s |
||
GND |
OFF (fixed) |
||
GROUND BOND |
|||
Output-Current Range |
03.00A~30.00A ac |
||
Output-Current Resolution |
0.01A |
||
Output-Current Accuracy |
3A?I?8A : ± (1% of setting +0.2A) 8A<I?30A : ± (1% of setting +0.05A) |
||
Test-Voltage |
6Vac max. (open circuit) |
||
Test-Voltage Frequency |
50 Hz / 60 Hz selectable |
||
Resistance Measurement Range |
10mW~650.0mW |
||
Resistance Measurement Resolution |
0.1mW |
||
Resistance Measurement Accuracy |
± (1% of reading +2mW) |
||
Window Comparator Method |
Yes |
||
TIMER (Test Time) |
0.5s~999.9s |
||
GND |
OFF (fixed) |
||
Test Method |
Four Terminal |
||
MEMORY |
|||
Single Step Memory |
MANU : 100 blocks |
||
Automatic Testing Memory |
AUTO : 100 blocks, menu per auto : 16 |
||
INTERFACE |
|||
RS232 |
Standard |
||
USB (Device) |
Standard |
||
GPIB |
Option |
||
Remote Terminal (Front) |
Standard |
||
SIGNAL IO |
Standard |
||
General |
|||
DISPLY |
240 x 64 dot matrix LED back light LCD |
||
POWER SOURCE |
AC100V/120V/220V/230V ±10%, 50/60Hz |
||
POWER CONSUMPTION |
500VA max. |
||
DIMENSIONS & WEIGHT |
330(W) x 148(H) x 452(D) mm (Max.), approx.19kg(Max) |
* The “TIMER OFF” can only be performed when the tester is in the special MANU mode
AC WITHSTANDING |
|||
Output-Voltage Range |
0.100kV~ 5.000kV ac |
||
Output-Voltage Resolution |
2V/step |
||
Output-Voltage Accuracy |
± (1% of setting +5V) [no load] |
||
Maximum Rated Load |
200 VA (5kV/40mA) |
||
Maximum Rated Current |
40mA (0.5kV < V ? 5kV) 10mA (0.1kV ? V? 0.5kV) |
||
Output-Voltage Waveform |
Sine wave |
||
Output-Voltage Frequency |
50 Hz / 60 Hz selectable |
||
Voltage regulation |
± (1% of reading +5V) [full load → no load] |
||
Voltmeter Accuracy |
± (1% of reading+ 5V) |
||
Current Measurement Range |
0.001mA~040.0mA |
||
Current Best Resolution |
0.001mA / 0.01mA / 0.1mA |
||
AC Current Measurement Accuracy |
±(1.5% of reading +30 counts) when HISET < 1.00mA ±(1.5% of reading +3 counts) when HISET ? 1.00mA |
||
Window Comparator Method |
Yes |
||
ARC Detect |
Yes |
||
RAMP (Ramp-Up Time) |
0.1~999.9s |
||
TIMER (Test Time)* |
OFF, 0.5s~999.9s |
||
GND |
ON/OFF |
||
DC WITHSTANDING |
|||
Output-Voltage Range |
0.100kV~ 6.000kV dc |
||
Output-Voltage Resolution |
2V/step |
||
Output-Voltage Accuracy |
± (1% of setting +5V) [no load] |
||
Maximum Rated Load |
50W (5kV/10mA) |
||
Maximum Rated Current |
10mA (0.5kV < V ? 6kV) 2mA (0.1kV ? V? 0.5kV) |
||
Voltage regulation |
± (1% of reading +5V) [full load → no load] |
||
Voltmeter Accuracy |
± (1% of reading+ 5V) |
||
Current Measurement Range |
0.001mA~010.0mA |
||
Current Best Resolution |
0.001mA / 0.01mA / 0.1mA |
||
DC Current Measurement Accuracy |
±(1.5% of reading +30 counts) when HISET < 1.00mA ±(1.5% of reading +3 counts) when HISET ? 1.00mA |
||
Window Comparator Method |
Yes |
||
ARC Detect |
Yes |
||
RAMP (Ramp-Up Time) |
0.1~999.9s |
||
TIMER (Test Time)* |
OFF, 0.5s~999.9s |
||
GND |
ON/OFF |
||
INSULATION RESISITANCE |
|||
Output-Voltage |
50V~1000V dc |
||
Output-Voltage Resolution |
50V/step |
||
Output-Voltage Accuracy |
± (1% of setting +5V) [no load] |
||
Resistance Measurement Range |
1 Mohm~ 9500 Mohm |
||
|
Test voltage |
Measurable Range |
Accuracy |
|
50V?V?450V |
1 Mohm~ 50 Mohm 51 Mohm~ 2000 Mohm |
±(5% of reading +1 count) ±(10% of reading +1 counts) |
|
500V?V?1000V |
1M ohm~ 500 Mohm 501 Mohm~ 9500 Mohm |
±(5% of reading +1 count) ±(10% of reading +1 count) |
Window Comparator Method |
Yes |
||
Output Impedance |
600 kohm |
||
RAMP (Ramp-Up Time) |
0.1~999.9s |
||
TIMER (Test Time) |
1s~999.9s |
||
GND |
OFF (fixed) |
||
GROUND BOND |
|||
Output-Current Range |
03.00A~30.00A ac |
||
Output-Current Resolution |
0.01A |
||
Output-Current Accuracy |
3A?I?8A : ± (1% of setting +0.2A) 8A<I?30A : ± (1% of setting +0.05A) |
||
Test-Voltage |
6Vac max. (open circuit) |
||
Test-Voltage Frequency |
50 Hz / 60 Hz selectable |
||
Resistance Measurement Range |
10mW~650.0mW |
||
Resistance Measurement Resolution |
0.1mW |
||
Resistance Measurement Accuracy |
± (1% of reading +2mW) |
||
Window Comparator Method |
Yes |
||
TIMER (Test Time) |
0.5s~999.9s |
||
GND |
OFF (fixed) |
||
Test Method |
Four Terminal |
||
MEMORY |
|||
Single Step Memory |
MANU : 100 blocks |
||
Automatic Testing Memory |
AUTO : 100 blocks, menu per auto : 16 |
||
INTERFACE |
|||
RS232 |
Standard |
||
USB (Device) |
Standard |
||
GPIB |
Option |
||
Remote Terminal (Front) |
Standard |
||
SIGNAL IO |
Standard |
||
General |
|||
DISPLY |
240 x 64 dot matrix LED back light LCD |
||
POWER SOURCE |
AC100V/120V/220V/230V ±10%, 50/60Hz |
||
POWER CONSUMPTION |
500VA max. |
||
DIMENSIONS & WEIGHT |
330(W) x 148(H) x 452(D) mm (Max.), approx.19kg(Max) |
* The “TIMER OFF” can only be performed when the tester is in the special MANU mode