 Model  GDS-307 GDS-310 GDS-320 GDS-207 GDS-210 GDS-220
 VERTICAL      
 Channels 2 (BNC-Shield)      
 Input Impedance 1MΩ±2%, 16.5pf approx.      
Maximum Input  CAT II 300VRMS     
Input Coupling  AC, DC, GND     
 Bandwidth  DC~70MHz (-3dB) DC~100MHz (-3dB)   DC~200MHz (-3dB) DC~70MHz (-3dB)  DC~100MHz (-3dB)   DC~200MHz (-3dB)
 Rise time  <5ns  <3.5ns <1.75ns  <5ns  <3.5ns  <1.75ns 
 Sensitivity  2mV/div~10V/div (1-2-5 increments)     
 Accuracy  ±(3% x Readout + 0.1 div + 1mV)     
 Bandwidth Limit  20MHz(-3dB)     
 Polarity  Normal, Invert     
Offset Position Range  2mV/div~50mV/div : ±0.4V
100mV/div~500mV/div : ±4V
1V/div~5V/div : ±40V
10V/div : ±300V     
 SIGNAL ACQUISITION      
 Realtime sample rate 1GSa/s      
 Memory depth 5M points per ch    1M points per ch   
 Acquisition mode  Average: 2~256 waveforms
Peak detect: 10ns
sin(x)/x or ET     
 Replay wfms. 30,000 wfms.
 TRIGGER      
 Source Ch1 or Ch2  
 Trigger mode Auto, Normal, Single, Force      
Trigger type Edge, Pulse Width, Video, Alternate   
 Trigger Holdoff 10ns ~ 10s      
Coupling AC, DC, LFR, HFR, NR  
 Sensitivity DC~25MHz: approx. 0.5div or 5mV
25MHz~ 70/100/200MHz: approx. 1.5div or 15mV      
 HORIZONTAL
 Range  5ns~100s/Div (1-2-5 increments)     
 Roll 100ms/div ~ 100s/div
Pre-trigger  10 div max.     
 Post_trigger 1,000 div max(depend on time base)
 Accuracy ±20ppm over any > 1ms time interval      
XY MODE
Phase Shift  ±3° at 100KHz     
CURSOR AND MEASUREMENT
 Cursors  Voltage difference between cursors(?V), Time difference between cursors(?T), frequency measure(1/?T)     
 Auto-measurement 36 sets.
 Auto-counter 6 digits. Range: 2Hz to rated bandwidth      
Autoset Available
 TEMPERATURE MEASUREMENT Available    Non-Available   
MISCELLANEOUS
Multi-Language Menu Available
 On-line Help Available
 Time and Clock Available
 BATTERY
Battery power Li-polymer 6100mA/hr, 7.4V (Built-in)      
 Charge time  2.0 hour (75%)     
 Operation time  4.1 hour, depending on operating condition.     
 PROBE COMPENSATION      
   2V, 1KHz, 50% Duty cycle     
 INTERFACE      
 USB  USB Device (Isolation)     
 Internal Flash Disk  120MB     
DISPLAY       
 Type  7 inch     
 Display resolution 480 x 800 pixels      
 Display direction  Landscape & Portrait     
 Backlight control  Manual adjustable, ECO mode     
 Touch panel  Capacitive     
 POWER ADAPTOR      
 Line Voltage  AC 100V~240V, 48~63Hz, Power Consumption 40W     
DC Output  DC Output: 12V/3A, Double Shield     
 OPTION      
 Differential Probe  Dual-channel, 40MHz, CAT II 600V     
 DIMENSIONS & WEIGHT      
  1.5Kg,  HxWxD(mm)  240mm x 136mm x60 mm      
 DMM (Digital Multi-Meter)  
 DIGIT LEVEL  50,000 counts    5,000 counts  
 CAT II 600VRMS, CAT III 300VRMS     
DC VOLTAGE       
 Range 50mV, 500mV, 5V, 50V, 500V,  1000V  6 ranges      
 Accuracy

GDS-307/310/320: 50mV, 500mV, 5V, 50V, 500V ±(0.05% + 5 digits), 1000V ±(0.1% + 5 digits) 

GDS-207/210/220: 50mV, 500mV, 5V, 50V, 500V, 1000V ±(0.1% + 5 digits)

Input Impedance 10MΩ      
             
 DC CURRENT            
 Range  50mA, 500mA,  10A   3 ranges     
 Accuracy GDS-307/310/320: 50mA - 500mA, 2 Ranges, ±(0.1% + 5 digits), 10A ±(0.5% + 1 digits) 
GDS-207/210/220: 50mA - 500mA, 10A 3 Ranges, ±(0.5% + 1 digits)      
             
 AC VOLTAGE            
 Range  50mV, 500mV, 5V, 50V, 700V  5 ranges     
 Accuracy  50mV, 500mV, 5V, 50V, 700V ±(1.5% + 15 digits) at 50Hz-1kHz     
             
 AC CURRENT            
 Range 50mA, 500mA, 10A 3 ranges      
 Accuracy  50mA, 500mA, ±(1.5% + 15 digits) at 50Hz-1kHz 
10A ±(3% + 15 digits) at 50Hz-1kHz

* Measure range: >10mA     
             
 RESISTANCE            
 Range 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 5 range      
 Accuracy 500Ω, 5kΩ, 50kΩ, 500kΩ ±(0.3% + 3 digits)
5MΩ ±(0.5% + 5 digits)

* Measure range: 50Ω to 5MΩ 
 DIODE TEST Maximum forward voltage 1.5V, Open voltage 2.8V      
             
 CONTINUITY BEEP  < 15 Ω     
             
 FUNCTIONS  Auto Range, Max, Min, Hold, Trend plot     
Tehniline info
 Model  GDS-307 GDS-310 GDS-320 GDS-207 GDS-210 GDS-220
 VERTICAL      
 Channels 2 (BNC-Shield)      
 Input Impedance 1MΩ±2%, 16.5pf approx.      
Maximum Input  CAT II 300VRMS     
Input Coupling  AC, DC, GND     
 Bandwidth  DC~70MHz (-3dB) DC~100MHz (-3dB)   DC~200MHz (-3dB) DC~70MHz (-3dB)  DC~100MHz (-3dB)   DC~200MHz (-3dB)
 Rise time  <5ns  <3.5ns <1.75ns  <5ns  <3.5ns  <1.75ns 
 Sensitivity  2mV/div~10V/div (1-2-5 increments)     
 Accuracy  ±(3% x Readout + 0.1 div + 1mV)     
 Bandwidth Limit  20MHz(-3dB)     
 Polarity  Normal, Invert     
Offset Position Range  2mV/div~50mV/div : ±0.4V
100mV/div~500mV/div : ±4V
1V/div~5V/div : ±40V
10V/div : ±300V     
 SIGNAL ACQUISITION      
 Realtime sample rate 1GSa/s      
 Memory depth 5M points per ch    1M points per ch   
 Acquisition mode  Average: 2~256 waveforms
Peak detect: 10ns
sin(x)/x or ET     
 Replay wfms. 30,000 wfms.
 TRIGGER      
 Source Ch1 or Ch2  
 Trigger mode Auto, Normal, Single, Force      
Trigger type Edge, Pulse Width, Video, Alternate   
 Trigger Holdoff 10ns ~ 10s      
Coupling AC, DC, LFR, HFR, NR  
 Sensitivity DC~25MHz: approx. 0.5div or 5mV
25MHz~ 70/100/200MHz: approx. 1.5div or 15mV      
 HORIZONTAL
 Range  5ns~100s/Div (1-2-5 increments)     
 Roll 100ms/div ~ 100s/div
Pre-trigger  10 div max.     
 Post_trigger 1,000 div max(depend on time base)
 Accuracy ±20ppm over any > 1ms time interval      
XY MODE
Phase Shift  ±3° at 100KHz     
CURSOR AND MEASUREMENT
 Cursors  Voltage difference between cursors(?V), Time difference between cursors(?T), frequency measure(1/?T)     
 Auto-measurement 36 sets.
 Auto-counter 6 digits. Range: 2Hz to rated bandwidth      
Autoset Available
 TEMPERATURE MEASUREMENT Available    Non-Available   
MISCELLANEOUS
Multi-Language Menu Available
 On-line Help Available
 Time and Clock Available
 BATTERY
Battery power Li-polymer 6100mA/hr, 7.4V (Built-in)      
 Charge time  2.0 hour (75%)     
 Operation time  4.1 hour, depending on operating condition.     
 PROBE COMPENSATION      
   2V, 1KHz, 50% Duty cycle     
 INTERFACE      
 USB  USB Device (Isolation)     
 Internal Flash Disk  120MB     
DISPLAY       
 Type  7 inch     
 Display resolution 480 x 800 pixels      
 Display direction  Landscape & Portrait     
 Backlight control  Manual adjustable, ECO mode     
 Touch panel  Capacitive     
 POWER ADAPTOR      
 Line Voltage  AC 100V~240V, 48~63Hz, Power Consumption 40W     
DC Output  DC Output: 12V/3A, Double Shield     
 OPTION      
 Differential Probe  Dual-channel, 40MHz, CAT II 600V     
 DIMENSIONS & WEIGHT      
  1.5Kg,  HxWxD(mm)  240mm x 136mm x60 mm      
 DMM (Digital Multi-Meter)  
 DIGIT LEVEL  50,000 counts    5,000 counts  
 CAT II 600VRMS, CAT III 300VRMS     
DC VOLTAGE       
 Range 50mV, 500mV, 5V, 50V, 500V,  1000V  6 ranges      
 Accuracy

GDS-307/310/320: 50mV, 500mV, 5V, 50V, 500V ±(0.05% + 5 digits), 1000V ±(0.1% + 5 digits) 

GDS-207/210/220: 50mV, 500mV, 5V, 50V, 500V, 1000V ±(0.1% + 5 digits)

Input Impedance 10MΩ      
             
 DC CURRENT            
 Range  50mA, 500mA,  10A   3 ranges     
 Accuracy GDS-307/310/320: 50mA - 500mA, 2 Ranges, ±(0.1% + 5 digits), 10A ±(0.5% + 1 digits) 
GDS-207/210/220: 50mA - 500mA, 10A 3 Ranges, ±(0.5% + 1 digits)      
             
 AC VOLTAGE            
 Range  50mV, 500mV, 5V, 50V, 700V  5 ranges     
 Accuracy  50mV, 500mV, 5V, 50V, 700V ±(1.5% + 15 digits) at 50Hz-1kHz     
             
 AC CURRENT            
 Range 50mA, 500mA, 10A 3 ranges      
 Accuracy  50mA, 500mA, ±(1.5% + 15 digits) at 50Hz-1kHz 
10A ±(3% + 15 digits) at 50Hz-1kHz

* Measure range: >10mA     
             
 RESISTANCE            
 Range 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 5 range      
 Accuracy 500Ω, 5kΩ, 50kΩ, 500kΩ ±(0.3% + 3 digits)
5MΩ ±(0.5% + 5 digits)

* Measure range: 50Ω to 5MΩ 
 DIODE TEST Maximum forward voltage 1.5V, Open voltage 2.8V      
             
 CONTINUITY BEEP  < 15 Ω     
             