Tehniline info

AC WITHSTANDING

Output-Voltage Range

0.100kV~ 5.000kV ac

Output-Voltage Resolution

2V/step

Output-Voltage Accuracy

± (1% of setting +5V) [no load]

Maximum Rated Load

200 VA (5kV/40mA)

Maximum Rated Current

40mA (0.5kV < V ? 5kV)

10mA (0.1kV ? V? 0.5kV)

Output-Voltage Waveform

Sine wave

Output-Voltage Frequency

50 Hz / 60 Hz selectable

Voltage regulation

± (1% of reading +5V) [full load → no load]

Voltmeter Accuracy

± (1% of reading+ 5V)

Current Measurement Range

0.001mA~040.0mA

Current Best Resolution

0.001mA / 0.01mA / 0.1mA

AC Current Measurement Accuracy

±(1.5% of reading +30 counts) when HISET < 1.00mA

±(1.5% of reading +3 counts) when HISET ? 1.00mA

Window Comparator Method

Yes

ARC Detect

Yes

RAMP (Ramp-Up Time)

0.1~999.9s

TIMER (Test Time)*

OFF, 0.5s~999.9s

GND

ON/OFF

DC WITHSTANDING

Output-Voltage Range

0.100kV~ 6.000kV dc

Output-Voltage Resolution

2V/step

Output-Voltage Accuracy

± (1% of setting +5V) [no load]

Maximum Rated Load

50W (5kV/10mA)

Maximum Rated Current

10mA (0.5kV < V ? 6kV)

2mA (0.1kV ? V? 0.5kV)

Voltage regulation

± (1% of reading +5V) [full load → no load]

Voltmeter Accuracy

± (1% of reading+ 5V)

Current Measurement Range

0.001mA~010.0mA

Current Best Resolution

0.001mA / 0.01mA / 0.1mA

DC Current Measurement Accuracy

±(1.5% of reading +30 counts) when HISET < 1.00mA

±(1.5% of reading +3 counts) when HISET ? 1.00mA

Window Comparator Method

Yes

ARC Detect

Yes

RAMP (Ramp-Up Time)

0.1~999.9s

TIMER (Test Time)*

OFF, 0.5s~999.9s

GND

ON/OFF

INSULATION RESISITANCE

Output-Voltage

50V~1000V dc

Output-Voltage Resolution

50V/step

Output-Voltage Accuracy

± (1% of setting +5V) [no load]

Resistance Measurement Range

1 Mohm~ 9500 Mohm

 

Test voltage

Measurable Range

Accuracy

 

50V?V?450V

1 Mohm~ 50 Mohm

51 Mohm~ 2000 Mohm

±(5% of reading +1 count)

±(10% of reading +1 counts)

 

500V?V?1000V

1M ohm~ 500 Mohm

501 Mohm~ 9500 Mohm

±(5% of reading +1 count)

±(10% of reading +1 count)

Window Comparator Method

Yes

Output Impedance

600 kohm

RAMP (Ramp-Up Time)

0.1~999.9s

TIMER (Test Time)

1s~999.9s

GND

OFF (fixed)

GROUND BOND

Output-Current Range

03.00A~30.00A ac

Output-Current Resolution

0.01A

Output-Current Accuracy

3A?I?8A : ± (1% of setting +0.2A)

8A<I?30A : ± (1% of setting +0.05A)

Test-Voltage

6Vac max. (open circuit)

Test-Voltage Frequency

50 Hz / 60 Hz selectable

Resistance Measurement Range

10mW~650.0mW

Resistance Measurement Resolution

0.1mW

Resistance Measurement Accuracy

± (1% of reading +2mW)

Window Comparator Method

Yes

TIMER (Test Time)

0.5s~999.9s

GND

OFF (fixed)

Test Method

Four Terminal

MEMORY

Single Step Memory

MANU : 100 blocks

Automatic Testing Memory

AUTO : 100 blocks, menu per auto : 16

INTERFACE

RS232

Standard

USB (Device)

Standard

GPIB

Option

Remote Terminal (Front)

Standard

SIGNAL IO

Standard

General

DISPLY

240 x 64 dot matrix LED back light LCD

POWER SOURCE

AC100V/120V/220V/230V ±10%, 50/60Hz

POWER CONSUMPTION

500VA max.

DIMENSIONS & WEIGHT

330(W) x 148(H) x 452(D) mm (Max.),

approx.19kg(Max)

 

* The “TIMER OFF” can only be performed when the tester is in the special MANU mode

Tehniline info

AC WITHSTANDING

Output-Voltage Range

0.100kV~ 5.000kV ac

Output-Voltage Resolution

2V/step

Output-Voltage Accuracy

± (1% of setting +5V) [no load]

Maximum Rated Load

200 VA (5kV/40mA)

Maximum Rated Current

40mA (0.5kV < V ? 5kV)

10mA (0.1kV ? V? 0.5kV)

Output-Voltage Waveform

Sine wave

Output-Voltage Frequency

50 Hz / 60 Hz selectable

Voltage regulation

± (1% of reading +5V) [full load → no load]

Voltmeter Accuracy

± (1% of reading+ 5V)

Current Measurement Range

0.001mA~040.0mA

Current Best Resolution

0.001mA / 0.01mA / 0.1mA

AC Current Measurement Accuracy

±(1.5% of reading +30 counts) when HISET < 1.00mA

±(1.5% of reading +3 counts) when HISET ? 1.00mA

Window Comparator Method

Yes

ARC Detect

Yes

RAMP (Ramp-Up Time)

0.1~999.9s

TIMER (Test Time)*

OFF, 0.5s~999.9s

GND

ON/OFF

DC WITHSTANDING

Output-Voltage Range

0.100kV~ 6.000kV dc

Output-Voltage Resolution

2V/step

Output-Voltage Accuracy

± (1% of setting +5V) [no load]

Maximum Rated Load

50W (5kV/10mA)

Maximum Rated Current

10mA (0.5kV < V ? 6kV)

2mA (0.1kV ? V? 0.5kV)

Voltage regulation

± (1% of reading +5V) [full load → no load]

Voltmeter Accuracy

± (1% of reading+ 5V)

Current Measurement Range

0.001mA~010.0mA

Current Best Resolution

0.001mA / 0.01mA / 0.1mA

DC Current Measurement Accuracy

±(1.5% of reading +30 counts) when HISET < 1.00mA

±(1.5% of reading +3 counts) when HISET ? 1.00mA

Window Comparator Method

Yes

ARC Detect

Yes

RAMP (Ramp-Up Time)

0.1~999.9s

TIMER (Test Time)*

OFF, 0.5s~999.9s

GND

ON/OFF

INSULATION RESISITANCE

Output-Voltage

50V~1000V dc

Output-Voltage Resolution

50V/step

Output-Voltage Accuracy

± (1% of setting +5V) [no load]

Resistance Measurement Range

1 Mohm~ 9500 Mohm

 

Test voltage

Measurable Range

Accuracy

 

50V?V?450V

1 Mohm~ 50 Mohm

51 Mohm~ 2000 Mohm

±(5% of reading +1 count)

±(10% of reading +1 counts)

 

500V?V?1000V

1M ohm~ 500 Mohm

501 Mohm~ 9500 Mohm

±(5% of reading +1 count)

±(10% of reading +1 count)

Window Comparator Method

Yes

Output Impedance

600 kohm

RAMP (Ramp-Up Time)

0.1~999.9s

TIMER (Test Time)

1s~999.9s

GND

OFF (fixed)

GROUND BOND

Output-Current Range

03.00A~30.00A ac

Output-Current Resolution

0.01A

Output-Current Accuracy

3A?I?8A : ± (1% of setting +0.2A)

8A<I?30A : ± (1% of setting +0.05A)

Test-Voltage

6Vac max. (open circuit)

Test-Voltage Frequency

50 Hz / 60 Hz selectable

Resistance Measurement Range

10mW~650.0mW

Resistance Measurement Resolution

0.1mW

Resistance Measurement Accuracy

± (1% of reading +2mW)

Window Comparator Method

Yes

TIMER (Test Time)

0.5s~999.9s

GND

OFF (fixed)

Test Method

Four Terminal

MEMORY

Single Step Memory

MANU : 100 blocks

Automatic Testing Memory

AUTO : 100 blocks, menu per auto : 16

INTERFACE

RS232

Standard

USB (Device)

Standard

GPIB

Option

Remote Terminal (Front)

Standard

SIGNAL IO

Standard

General

DISPLY

240 x 64 dot matrix LED back light LCD

POWER SOURCE

AC100V/120V/220V/230V ±10%, 50/60Hz

POWER CONSUMPTION

500VA max.

DIMENSIONS & WEIGHT

330(W) x 148(H) x 452(D) mm (Max.),

approx.19kg(Max)

 

* The “TIMER OFF” can only be performed when the tester is in the special MANU mode