Fluke 1663 Multifunction Installation Tester is the ideal choice for hard working professionals

The 1663 installation tester delivers the full-featured functionality and advanced measurement capabilities that professional installers need. It is compact and lightweight (less than 1.3 kg) and comes with a padded carrying and waist strap for convenient handling. Operation is intuitive and easily mastered by all levels of workers so you can put it to work immediately for quick and efficient testing to all local regulations. Additional helpful features like On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.

Other useful capabilities:

  • Checks wiring polarity to detect broken N wires
  • Measures insulation resistance and loop and line resistance
  • Includes Z-max memory for loop tests to support easy evaluation of the highest loop test value
  • Provides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation
  • Measures motor windings with continuity test
  • Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)
  • Measures RCD switching time and tripping level (ramp test)
  • Measures trip time and current for RCD type A & AC in one test
  • Measures RCD variable current
  • Provides automatic RCD test sequence
  • Includes a phase sequence indicator
  • Safety rated CAT III 500V, CAT IV 300V
  • Comes with hard carrying case, padded carrying and waist strap, and remote control probe and lead

___________________________________________________________________________________________________________

FLUKE T6 Product Highlights

  • FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage*
  • 1 to 600 V ac or dc (T6-600)
  • 0 to 200 A ac
  • True-rms voltage and current
  • Resistance 1 Ω to 100 kΩ
  • Frequency measurement 45 Hz to 66 Hz
  • Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
  • HOLD button temporarily freezes the reading for easy viewing
  • Easy to read display with backlight
  • Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
  • Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase+

Tips: FieldSense Technology

Do not hold or touch wire you are testing during a measurement. Use the black probe to make the ground connection if:

  • wearing gloves or insulated footwear
  • standing on an insulated ladder
  • additional ground contact is required for the application

FieldSense measurement looks like this when properly grounded:

  • Display color turns green
  • Display shows a valid measurement >16 V rather than dashes or 0.0
  • shows for measurement ≥30 V

 

Specifications: Fluke 1663 Multifunction Testers

AC voltage measurement

Range

500 V

Resolution

0.1 V

Accuracy 45 Hz – 66 Hz

0.8% + 3

Input impedance

360 kΩ

Overload protection

660 V rms

Continuity testing (RLO)

Range (autoranging)

20 Ω / 200 Ω / 2000 Ω

Resolution

0.01 Ω / 0.1 Ω / 1 Ω

Open Circuit Voltage

>4 V

Insulation resistance measurement (RISO)

Test voltages

50-100-250-500-1000 V

Accuracy of tTest voltage (at rated test current)

+10%, -0%

Test voltage

50 V
100 V
250 V
500 V
1000 V

Insulation resistance range

20 MΩ /50 MΩ
20 MΩ / 100 MΩ
20 MΩ / 200 MΩ
20 MΩ / 200 MΩ / 500 MΩ
20 MΩ / 200 MΩ / 1000 MΩ

Resolution

0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ

Test current

1 mA @ 50 kΩ
1 mA @ 100 kΩ
1 mA @ 250 kΩ
1 mA @ 500 kΩ
1 mA @ 1 MΩ

Loop and line impedance (ZI)

Range

10 Ω / 0.001 Ω / High current mΩ mode

Resolution

0.01 Ω / 0.1 Ω / 1 Ω

Prospective earth fault current, PSC test

Range

1000 A / 10 kA (50 kA)

Resolution

1 A / 0.1 kA

Computation

Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.

RCD testing, RCD types tested

RCD Type

AC¹
G²,S³

Model 1663

A4, AC¹, G²,S³

Notes

¹Responds to AC
²General, no delay
³Time delay
4Responds to pulsed signal
5Responds to smooth DC signal

Tripping speed test (ΔT)

Current settings¹

10-30-100-300-500-1000 mA – VAR
10-30-100 mA

Multiplier

x ½, x 1
x 5

Measurement range

RCD Type G

310 ms
50 ms

RCD Type S

510 ms
160 ms

Notes

¹1000 mA type AC only
700 mA maximum type A in VAR mode
VAR mode not available for type B.

RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)

Current range

30% to 110% of RCD rated current¹

Step size

10% of IΔN²

Dwell time

Type G

300 ms/step

Type S

500 ms/step

Measurement accuracy

±5%

Specified trip current ranges (EN 61008-1)

50% to 100% for Type AC
35% to 140% for Type A (>10 mA)
35% to 200% for Type A (≤10 mA)
50% to 200% for Type B
²5% for Type B

Notes

¹30% to 150% for Type A IΔN > 10 mA
30% to 210% for Type A IΔN = 10 mA
20% to 210% for Type B

Earth Resistance Test (RE)

Range

200 Ω / 2000 Ω

Resolution

0.1 Ω / 1Ω

Frequency

128 Hz

Output Voltage

25 V

Phase Sequence Indication

General Specifications

Size (L x W x H)

10 x 25 x 12.5 cm

Weight (incl. batteries)

1.3 Kg

Battery size, quantity

Type AA, 6 ea.

Sealing

IP-40

Safety

Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition

Overvoltage

CAT III / 500V; CAT IV 300V

Performance

EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition

 