Moxa's Layer 2 managed switches feature industrial-grade reliability, network redundancy, and security features based on the IEC 62443 standard. We offer toughened, industry-specific products with multiple industry certifications, such as parts of the EN 50155 standard for rail applications, IEC 61850-3 for power automation systems, and NEMA TS2 for intelligent transportation systems.

                         Features and Benefits

  • 4 Gigabit plus 14 fast Ethernet ports for copper and fiber
  • Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250 switches), Gigabit Ethernet recovery time < 50 ms RSTP/STP, and MSTP for network redundancy
  • RADIUS, TACACS+, MAB Authentication, SNMPv3, IEEE 802.1X, MAC ACL, HTTPS, SSH, and sticky MAC-addresses to enhance network security
  • Security features based on IEC 62443
  • EtherNet/IP, PROFINET, and Modbus TCP protocols supported for device management and monitoring
  • Fiber Check™—comprehensive fiber status monitoring and warning on MST/MSC/SSC/SFP fiber ports
  • Supports MXstudio for easy, visualized industrial network management
  • V-ON™ ensures millisecond-level multicast data and video network recovery
  • Introduction

    The EDS-518E standalone, compact 18-port managed Ethernet switches have 4 combo Gigabit ports with built-in RJ45 or SFP slots for Gigabit fiber-optic communication. The 14 fast Ethernet ports have a variety of copper and fiber port combinations that give the EDS-518E Series greater flexibility for designing your network and application. The Ethernet redundancy technologies Turbo Ring, Turbo Chain, RSTP/STP, and MSTP increase the system reliability and availability of your network backbone. The EDS-518E also supports advanced management and security features.

    In addition, the EDS-518E Series is designed specifically for harsh industrial environments with limited installation space and high protection level requirements, such as maritime, rail wayside, oil and gas, factory automation, and process automation.

     

    Additional Features and Benefits

    • DHCP Option 82 for IP address assignment with different policies

    • Supports EtherNet/IP, PROFINET, and Modbus TCP protocols for device management and monitoring

    • IGMP snooping and GMRP for filtering multicast traffic

    • Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network planning

    • QoS (IEEE 802.1p/1Q and TOS/DiffServ) to increase determinism

    • Port Trunking for optimum bandwidth utilization

    • Port mirroring for online debugging

    • Automatic warning by exception through email and relay output

    • SNMPv1/v2c/v3 for different levels of network management

    • RMON for proactive and efficient network monitoring

    • Fiber Check™ provides a comprehensive fiber Digital Diagnostic Monitoring (DDM) function and event warning on MST/MSC/SSC/SFP fiber ports

    • Bandwidth management to prevent unpredictable network status

    • Lock port function for blocking unauthorized access based on MAC address

    • Supports the ABC-02-USB (Automatic Backup Configurator) for system configuration backup/restore and firmware upgrade

  • Alarm Contact Channels

    1, Relay output with current carrying capacity of 1 A @ 24 VDC

  • Buttons

    Reset button

  • Digital Input Channels

    1

  • Digital Inputs

    +13 to +30 V for state 1
    -30 to +3 V for state 0
    Max. input current: 8 mA

 
  • 10/100BaseT(X) Ports (RJ45 connector)

    EDS-518E-4GTXSFP: 14
    EDS-518E-MM-SC-4GTXSFP/MM-ST-4GTXSFP/SS-SC-4GTXSFP: 12

    All models support:
    Auto negotiation speed
    Full/Half duplex mode
    Auto MDI/MDI-X connection

  • Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP+)

    4

  • 10/100/1000BaseT(X) Ports (RJ45 connector)

    Auto negotiation speed
    Full/Half duplex mode
    Auto MDI/MDI-X connection

  • 100BaseFX Ports (multi-mode SC connector)

    EDS-518E-MM-SC-4GTXSFP Series: 2

  • 100BaseFX Ports (multi-mode ST connector)

    EDS-518E-MM-ST-4GTXSFP Series: 2

  • 100BaseFX Ports (single-mode SC connector)

    EDS-518E-SS-SC-4GTXSFP Series: 2

  • Optical Fiber

     

  • Optical Fiber

     

     

  •  

  • Standards

    IEEE 802.3 for 10BaseT
    IEEE 802.3u for 100BaseT(X) and 100BaseFX
    IEEE 802.3ab for 1000BaseT(X)
    IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
    IEEE 802.3x for flow control
    IEEE 802.1D-2004 for Spanning Tree Protocol
    IEEE 802.1w for Rapid Spanning Tree Protocol
    IEEE 802.1s for Multiple Spanning Tree Protocol
    IEEE 802.1p for Class of Service
    IEEE 802.1Q for VLAN Tagging
    IEEE 802.1X for authentication
    IEEE 802.3ad for Port Trunk with LACP

 
  • Filter

    802.1Q VLAN, Port-based VLAN, GVRP, IGMP v1/v2/v3, GMRP

  • Industrial Protocols

    EtherNet/IP, Modbus TCP, PROFINET IO Device (Slave)

  • Management

    LLDP, Back Pressure Flow Control, BOOTP, Port Mirror, DHCP Option 66/67/82, DHCP Server/Client, Fiber check, Flow control, IPv4/IPv6, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTP

  • MIB

    Ethernet-like MIB, MIB-II, Bridge MIB, P-BRIDGE MIB, Q-BRIDGE MIB, RMON MIB Groups 1, 2, 3, 9, RSTP MIB

  • Redundancy Protocols

    Link Aggregation, MSTP, RSTP, STP, Turbo Chain, Turbo Ring v1/v2

  • Security

    Broadcast storm protection, HTTPS/SSL, TACACS+, SNMPv3, MAB authentication, Sticky MAC, NTP authentication, MAC ACL, Port Lock, RADIUS, SSH, SMTP with TLS

  • Time Management

    NTP Server/Client, SNTP

 
  • IGMP Groups

    2048

  • MAC Table Size

    16 K

  • Max. No. of VLANs

    64

  • Packet Buffer Size

    1 Mbits

  • Priority Queues

    4

  • VLAN ID Range

    VID 1 to 4094

 
  • Storage Port

    USB Type A

 
  • LED Indicators

    PWR1, PWR2, STATE, FAULT, 10/100M (TP port), 100M (fiber port), Gigabit combo port, MSTR/HEAD, CPLR/TAIL

 
  • Console Port

    USB-serial console (Type B connector)

 
  • DIP Switches

    Turbo Ring, Master, Coupler, Reserve

 
  • Connection

    2 removable 4-contact terminal block(s)

  • Input Current

    EDS-518E-4GTXSFP Series: 0.37 A @ 24 VDC
    EDS-518E-MM-SC-4GTXSFP/MM-ST-4GTXSFP/SS-SC-4GTXSFP: 0.41 A @ 24 VDC

  • Input Voltage

    12/24/48/-48 VDC, Redundant dual inputs

  • Operating Voltage

    9.6 to 60 VDC

  • Overload Current Protection

    Supported

  • Reverse Polarity Protection

    Supported

 
  • Housing

    Metal

  • IP Rating

    IP30

  • Dimensions

    94 x 135 x 137 mm (3.7 x 5.31 x 5.39 in)

  • Weight

    1518 g (3.35 lb)

  • Installation

    DIN-rail mounting, Wall mounting (with optional kit)

 
  • Operating Temperature

    Standard Models: -10 to 60°C (14 to 140°F)
    Wide Temp. Models: -40 to 75°C (-40 to 167°F)

  • Storage Temperature (package included)

    -40 to 85°C (-40 to 185°F)

  • Ambient Relative Humidity

    5 to 95% (non-condensing)

 
  • Safety

    UL 508, EN 60950-1 (LVD)

  • EMC

    EN 61000-6-2/-6-4

  • EMI

    CISPR 32, FCC Part 15B Class A

  • EMS

    IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
    IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
    IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
    IEC 61000-4-6 CS: 10 V
    IEC 61000-4-8 PFMF

  • Hazardous Locations

    ATEX, Class I Division 2

  • Maritime

    DNV-GL, LR, ABS, NK

  • Power Substation

    IEC 61850-3, IEEE 1613

  • Railway

    EN 50121-4

  • Traffic Control

    NEMA TS2

  • Shock

    IEC 60068-2-27

  • Freefall

    IEC 60068-2-32

  • Vibration

    IEC 60068-2-6

 
  • Time

    723,953 hrs

  • Standards

    Telcordia (Bellcore), GB

 

 

  • Warranty Period

    5 years