Muundur 1-portiga PROFIBUS- Modbus/EtherNet/IP, 12-48 VDC, 0 - 60°C
Võta ühendust
Tellimused ja päringud
info@yeint.eeTehniline informatsioon ja projektid
Ott-Kaarel Purru ott-kaarel.purru@yeint.eeKaal | 0 g |
---|---|
Mõõtühik | tk |
Tootekood | MOX900990 |
Osa number | MGate 5103 |
Kaubamärk | MOXA |
Estonia
Tellimuse järgi
Converts Modbus, or EtherNet/IP to PROFINET
Supports PROFINET IO device
Supports Modbus RTU/ASCII/TCP master/client and slave/server
Supports EtherNet/IP Adapter
Effortless configuration via web-based wizard
Built-in Ethernet cascading for easy wiring
Embedded traffic monitoring/diagnostic information for easy troubleshooting
microSD card for configuration backup/duplication and event logs
Status monitoring and fault protection for easy maintenance
Serial port with 2 kV isolation protection
-40 to 75°C wide operating temperature models available
Supports redundant dual DC power inputs and 1 relay output
Security features based on IEC 62443
Introduction
The MGate 5103 is an industrial Ethernet gateway for converting Modbus RTU/ASCII/TCP or EtherNet/IP to PROFINET-based network communications. To integrate existing Modbus devices onto a PROFINET network, use the MGate 5103 as a Modbus master/slave or EtherNet/IP adapter to collect data and exchange data with PROFINET devices. The latest exchange data will be stored in the gateway. The gateway will convert stored Modbus or EtherNet/IP data into PROFINET packets so the PROFINET IO Controller can control or monitor field devices.
Easy Configuration via Web Console
The MGate 5103 Series comes with an illustrated Quick Setup guide designed to make configuration easy. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps. The MGate 5103 Series also supports a GSDML export function. GSDML files can be imported into PROFINET PLCs to save time on PLC configuration.
Modbus RTU/ASCII/TCP Protocol Traffic Monitor
MGate 5103 gateways support Modbus RTU/ASCII/TCP Protocol Traffic Monitor for easy troubleshooting, especially during the installation stage. Communication issues could be caused by incorrect software parameters, such as slave IDs and register addresses, that were entered incorrectly, or an incorrect command configuration. With Modbus RTU/ASCII/TCP Protocol Traffic Monitor, you can check the captured data and easily identify the root cause.
Maintenance Functions
MGate 5103 gateways support a system log function that records events in the MGate; users can easily review log data remotely through the web console. The gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators.
-
10/100BaseT(X) Ports (RJ45 connector)
2
Auto MDI/MDI-X connection -
Magnetic Isolation Protection
1.5 kV (built-in)
-
Industrial Protocols
PROFINET IO Device, Modbus TCP Client (Master), Modbus TCP Server (Slave), EtherNet/IP Adapter
-
Configuration Options
Web Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console
-
Management
ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, SSH, UDP, NTP Client
-
MIB
RFC1213, RFC1317
-
Time Management
NTP Client
-
Console Port
RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
-
No. of Ports
1
-
Connector
DB9 male
-
Serial Standards
RS-232/422/485
-
Baudrate
50 bps to 921.6 kbps
-
Data Bits
7, 8
-
Parity
None, Even, Odd, Space, Mark
-
Stop Bits
1, 2
-
Flow Control
RTS Toggle (RS-232 only), RTS/CTS
-
RS-485 Data Direction Control
ADDC® (automatic data direction control)
-
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
-
Terminator for RS-485
120 ohms
-
Isolation
2 kV (built-in)
-
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
-
RS-422
Tx+, Tx-, Rx+, Rx-, GND
-
RS-485-2w
Data+, Data-, GND
-
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
-
Configuration Options
Serial Console
-
Industrial Protocols
Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave
-
Mode
Master, Slave
-
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
-
Max. No. of Commands
128
-
Input Data Size
512 bytes
-
Output Data Size
512 bytes
-
Mode
Client (Master), Server (Slave)
-
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
-
Max. No. of Client Connections
16
-
Max. No. of Server Connections
32
-
Max. No. of Commands
128
-
Input Data Size
512 bytes
-
Output Data Size
512 bytes
-
Mode
IO Device
-
Max. No. of IO Controller Connections
1 (for read/write)
-
Input Data Size
512 bytes
-
Output Data Size
512 bytes
-
Mode
Adapter
-
CIP Objects Supported
Identity, Message Router, Assembly, Connection Manager, TCP/IP interface, Ethernet link, Port
-
Max. No. of Scanner Connections
1 (for read-only), 1 (for read/write)
-
Input Data Size
496 bytes
-
Output Data Size
496 bytes
-
microSD Slot
Up to 32 GB (SD 2.0 compatible)
-
Input Voltage
12 to 48 VDC
-
Input Current
455 mA @ 12 VDC
-
Power Connector
Screw-fastened Euroblock terminal
-
Contact Current Rating
Resistive load: 2 A @ 30 VDC
-
Housing
Metal
-
IP Rating
IP30
-
Dimensions
36 x 105 x 140 mm (1.42 x 4.14 x 5.51 in)
-
Weight
507 g (1.12 lb)
-
Operating Temperature
MGate 5103: 0 to 60°C (32 to 140°F)
MGate 5103-T: -40 to 75°C (-40 to 167°F) -
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
5 to 95% (non-condensing)
-
Safety
EN 60950-1, UL 508
-
EMC
EN 55032/24
-
EMI
CISPR 32, FCC Part 15B Class B
-
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF -
Hazardous Locations
ATEX, Class I Division 2, IECEx
-
Freefall
IEC 60068-2-32
-
Shock
IEC 60068-2-27
-
Vibration
IEC 60068-2-6, IEC 60068-2-64
-
Time
859,422 hrs
-
Standards
Telcordia SR332
-
Warranty Period
5 years
Converts Modbus, or EtherNet/IP to PROFINET
Supports PROFINET IO device
Supports Modbus RTU/ASCII/TCP master/client and slave/server
Supports EtherNet/IP Adapter
Effortless configuration via web-based wizard
Built-in Ethernet cascading for easy wiring
Embedded traffic monitoring/diagnostic information for easy troubleshooting
microSD card for configuration backup/duplication and event logs
Status monitoring and fault protection for easy maintenance
Serial port with 2 kV isolation protection
-40 to 75°C wide operating temperature models available
Supports redundant dual DC power inputs and 1 relay output
Security features based on IEC 62443
Introduction
The MGate 5103 is an industrial Ethernet gateway for converting Modbus RTU/ASCII/TCP or EtherNet/IP to PROFINET-based network communications. To integrate existing Modbus devices onto a PROFINET network, use the MGate 5103 as a Modbus master/slave or EtherNet/IP adapter to collect data and exchange data with PROFINET devices. The latest exchange data will be stored in the gateway. The gateway will convert stored Modbus or EtherNet/IP data into PROFINET packets so the PROFINET IO Controller can control or monitor field devices.
Easy Configuration via Web Console
The MGate 5103 Series comes with an illustrated Quick Setup guide designed to make configuration easy. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps. The MGate 5103 Series also supports a GSDML export function. GSDML files can be imported into PROFINET PLCs to save time on PLC configuration.
Modbus RTU/ASCII/TCP Protocol Traffic Monitor
MGate 5103 gateways support Modbus RTU/ASCII/TCP Protocol Traffic Monitor for easy troubleshooting, especially during the installation stage. Communication issues could be caused by incorrect software parameters, such as slave IDs and register addresses, that were entered incorrectly, or an incorrect command configuration. With Modbus RTU/ASCII/TCP Protocol Traffic Monitor, you can check the captured data and easily identify the root cause.
Maintenance Functions
MGate 5103 gateways support a system log function that records events in the MGate; users can easily review log data remotely through the web console. The gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device and then issues alarms to notify operators.
-
10/100BaseT(X) Ports (RJ45 connector)
2
Auto MDI/MDI-X connection -
Magnetic Isolation Protection
1.5 kV (built-in)
-
Industrial Protocols
PROFINET IO Device, Modbus TCP Client (Master), Modbus TCP Server (Slave), EtherNet/IP Adapter
-
Configuration Options
Web Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console
-
Management
ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, SSH, UDP, NTP Client
-
MIB
RFC1213, RFC1317
-
Time Management
NTP Client
-
Console Port
RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
-
No. of Ports
1
-
Connector
DB9 male
-
Serial Standards
RS-232/422/485
-
Baudrate
50 bps to 921.6 kbps
-
Data Bits
7, 8
-
Parity
None, Even, Odd, Space, Mark
-
Stop Bits
1, 2
-
Flow Control
RTS Toggle (RS-232 only), RTS/CTS
-
RS-485 Data Direction Control
ADDC® (automatic data direction control)
-
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
-
Terminator for RS-485
120 ohms
-
Isolation
2 kV (built-in)
-
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
-
RS-422
Tx+, Tx-, Rx+, Rx-, GND
-
RS-485-2w
Data+, Data-, GND
-
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
-
Configuration Options
Serial Console
-
Industrial Protocols
Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave
-
Mode
Master, Slave
-
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
-
Max. No. of Commands
128
-
Input Data Size
512 bytes
-
Output Data Size
512 bytes
-
Mode
Client (Master), Server (Slave)
-
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
-
Max. No. of Client Connections
16
-
Max. No. of Server Connections
32
-
Max. No. of Commands
128
-
Input Data Size
512 bytes
-
Output Data Size
512 bytes
-
Mode
IO Device
-
Max. No. of IO Controller Connections
1 (for read/write)
-
Input Data Size
512 bytes
-
Output Data Size
512 bytes
-
Mode
Adapter
-
CIP Objects Supported
Identity, Message Router, Assembly, Connection Manager, TCP/IP interface, Ethernet link, Port
-
Max. No. of Scanner Connections
1 (for read-only), 1 (for read/write)
-
Input Data Size
496 bytes
-
Output Data Size
496 bytes
-
microSD Slot
Up to 32 GB (SD 2.0 compatible)
-
Input Voltage
12 to 48 VDC
-
Input Current
455 mA @ 12 VDC
-
Power Connector
Screw-fastened Euroblock terminal
-
Contact Current Rating
Resistive load: 2 A @ 30 VDC
-
Housing
Metal
-
IP Rating
IP30
-
Dimensions
36 x 105 x 140 mm (1.42 x 4.14 x 5.51 in)
-
Weight
507 g (1.12 lb)
-
Operating Temperature
MGate 5103: 0 to 60°C (32 to 140°F)
MGate 5103-T: -40 to 75°C (-40 to 167°F) -
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
5 to 95% (non-condensing)
-
Safety
EN 60950-1, UL 508
-
EMC
EN 55032/24
-
EMI
CISPR 32, FCC Part 15B Class B
-
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF -
Hazardous Locations
ATEX, Class I Division 2, IECEx
-
Freefall
IEC 60068-2-32
-
Shock
IEC 60068-2-27
-
Vibration
IEC 60068-2-6, IEC 60068-2-64
-
Time
859,422 hrs
-
Standards
Telcordia SR332
-
Warranty Period
5 years