1-portiga Modbus RTU/ASCII/TCP/IEC 101-to-IEC 104 gateways, -40 to 75°C
Võta ühendust
Tellimused ja päringud
info@yeint.eeTehniline informatsioon ja projektid
Ott-Kaarel Purru ott-kaarel.purru@yeint.eeKaal | 622 g |
---|---|
Mõõtühik | tk |
Tootekood | MOX900991 |
Osa number | MGate 5114-T |
Kaubamärk | MOXA |
Estonia
Tellimuse järgi
Protocol conversion between Modbus RTU/ASCII/TCP, IEC 60870-5-101, and IEC 60870-5-104
Supports IEC 60870-5-101 master/slave (balanced/unbalanced)
Supports IEC 60870-5-104 client/server
Supports Modbus RTU/ASCII/TCP master/client and slave/server
Effortless configuration via web-based wizard
Status monitoring and fault protection for easy maintenance
Embedded traffic monitoring/diagnostic information for easy troubleshooting
microSD card for configuration backup/duplication and event logs
Built-in Ethernet cascading for easy wiring
Redundant dual DC power inputs and relay output
-40 to 75°C wide operating temperature models available
Serial port with 2 kV isolation protection
Security features based on IEC 62443,
Introduction
The MGate 5114 is an industrial Ethernet gateway with 2 Ethernet ports and 1 RS-232/422/485 serial port for Modbus RTU/ASCII/TCP, IEC 60870-5-101, and IEC 60870-5-104 network communications. By integrating commonly used power protocols, the MGate 5114 provides the flexibility needed to fulfill the various conditions that arise with field devices that use different communications protocols to connect to a power SCADA system. To integrate Modbus or IEC 60870-5-101 devices onto an IEC 60870-5-104 network, use the MGate 5114 as a Modbus master/client or IEC 60870-5-101 master to collect data and exchange data with IEC 60870-5-104 systems.
Easy Configuration via Web Console
The MGate 5114 Series comes with an illustrated Quick Setup guide designed to make configuration easy. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps.
Modbus RTU/ASCII/TCP Protocol Traffic Monitor
MGate 5114 Series gateways support Modbus RTU/ASCII/TCP, IEC 60870-5-101, and IEC 60870-5-104 Protocol Traffic Monitor for easy troubleshooting, especially during the installation stage. It is worth mentioning that traffic logs can be viewed in the popular troubleshooting tool, Wireshark. With this feature, you can easily analyze traffic to determine the root cause of a problem.
Maintenance Functions
MGate 5114 gateways support a system log function that records events in the MGate; users can easily review log data remotely through the web console. The gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PSCADA system when a device gets disconnected or does not respond, in which case the PSCADA system gets the status of each end device and then issues alarms to notify operators.
-
10/100BaseT(X) Ports (RJ45 connector)
2
Auto MDI/MDI-X connection -
Magnetic Isolation Protection
1.5 kV (built-in)
-
Industrial Protocols
Modbus TCP Client (Master), Modbus TCP Server (Slave), IEC 60870-5-104 Client, IEC 60870-5-104 Server
-
Configuration Options
Web Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console
-
Management
ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, SSH, UDP, NTP Client
-
MIB
RFC1213, RFC1317
-
Time Management
NTP Client
-
Console Port
RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
-
No. of Ports
1
-
Connector
DB9 male
-
Serial Standards
RS-232/422/485
-
Baudrate
50 bps to 921.6 kbps
-
Data Bits
7, 8
-
Parity
Even, Mark, None, Odd, Space
-
Stop Bits
1, 2
-
Flow Control
RTS Toggle (RS-232 only), RTS/CTS
-
RS-485 Data Direction Control
ADDC® (automatic data direction control)
-
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
-
Terminator for RS-485
120 ohms
-
Isolation
2 kV (built-in)
-
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
-
RS-422
Tx+, Tx-, Rx+, Rx-, GND
-
RS-485-2w
Data+, Data-, GND
-
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
-
Industrial Protocols
Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave, IEC 60870-5-101 Master (Balanced/Unbalanced), IEC 60870-5-101 Slave (Balanced/Unbalanced)
-
Configuration Options
Serial Console
-
Mode
Master, Slave
-
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
-
Max. No. of Commands
128
-
Mode
Client (Master), Server (Slave)
-
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
-
Max. No. of Client Connections
32
-
Max. No. of Server Connections
32
-
Max. No. of Commands
128
-
Mode
Client
Server -
Max. No. of Client Connections
32
-
Max. No. of Server Connections
32
-
Max. No. of Information Objects
2000 points
-
Mode
Master (Balanced/Unbalanced)
Slave (Balanced/Unbalanced) -
Max. No. of Master Connections
1
-
Max. No. of Slave Connections
1 (Balanced), 31 (Unbalanced)
-
Max. No. of Information Objects
2000 points
-
microSD Slot
Up to 32 GB (SD 2.0 compatible)
-
Input Voltage
12 to 48 VDC
-
Input Current
455 mA @ 12 VDC
-
Power Connector
Screw-fastened Euroblock terminal
-
Contact Current Rating
Resistive load: 2 A @ 30 VDC
-
Housing
Metal
-
IP Rating
IP30
-
Dimensions
36 x 105 x 140 mm (1.42 x 4.14 x 5.51 in)
-
Weight
507 g (1.12 lb)
-
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
5 to 95% (non-condensing)
-
Operating Temperature
MGate 5114: 0 to 60°C (32 to 140°F)
MGate 5114-T: -40 to 75°C (-40 to 167°F)
-
Safety
EN 60950-1, UL 508
-
EMC
EN 55032/24
-
EMI
CISPR 32, FCC Part 15B Class B
-
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF -
Hazardous Locations
ATEX, Class I Division 2, IECEx Class 1 Division 2, ATEX, and IECEx certifications are underway. Please contact a Moxa sales representative for details.
-
Freefall
IEC 60068-2-32
-
Shock
IEC 60068-2-27
-
Vibration
IEC 60068-2-6, IEC 60068-2-64
-
Time
1,140,815 hrs
-
Standards
Telcordia SR332
-
Warranty Period
5 years
Protocol conversion between Modbus RTU/ASCII/TCP, IEC 60870-5-101, and IEC 60870-5-104
Supports IEC 60870-5-101 master/slave (balanced/unbalanced)
Supports IEC 60870-5-104 client/server
Supports Modbus RTU/ASCII/TCP master/client and slave/server
Effortless configuration via web-based wizard
Status monitoring and fault protection for easy maintenance
Embedded traffic monitoring/diagnostic information for easy troubleshooting
microSD card for configuration backup/duplication and event logs
Built-in Ethernet cascading for easy wiring
Redundant dual DC power inputs and relay output
-40 to 75°C wide operating temperature models available
Serial port with 2 kV isolation protection
Security features based on IEC 62443,
Introduction
The MGate 5114 is an industrial Ethernet gateway with 2 Ethernet ports and 1 RS-232/422/485 serial port for Modbus RTU/ASCII/TCP, IEC 60870-5-101, and IEC 60870-5-104 network communications. By integrating commonly used power protocols, the MGate 5114 provides the flexibility needed to fulfill the various conditions that arise with field devices that use different communications protocols to connect to a power SCADA system. To integrate Modbus or IEC 60870-5-101 devices onto an IEC 60870-5-104 network, use the MGate 5114 as a Modbus master/client or IEC 60870-5-101 master to collect data and exchange data with IEC 60870-5-104 systems.
Easy Configuration via Web Console
The MGate 5114 Series comes with an illustrated Quick Setup guide designed to make configuration easy. With Quick Setup, you can easily access protocol conversion modes and finish the configuration in a few steps.
Modbus RTU/ASCII/TCP Protocol Traffic Monitor
MGate 5114 Series gateways support Modbus RTU/ASCII/TCP, IEC 60870-5-101, and IEC 60870-5-104 Protocol Traffic Monitor for easy troubleshooting, especially during the installation stage. It is worth mentioning that traffic logs can be viewed in the popular troubleshooting tool, Wireshark. With this feature, you can easily analyze traffic to determine the root cause of a problem.
Maintenance Functions
MGate 5114 gateways support a system log function that records events in the MGate; users can easily review log data remotely through the web console. The gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PSCADA system when a device gets disconnected or does not respond, in which case the PSCADA system gets the status of each end device and then issues alarms to notify operators.
-
10/100BaseT(X) Ports (RJ45 connector)
2
Auto MDI/MDI-X connection -
Magnetic Isolation Protection
1.5 kV (built-in)
-
Industrial Protocols
Modbus TCP Client (Master), Modbus TCP Server (Slave), IEC 60870-5-104 Client, IEC 60870-5-104 Server
-
Configuration Options
Web Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console
-
Management
ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, SSH, UDP, NTP Client
-
MIB
RFC1213, RFC1317
-
Time Management
NTP Client
-
Console Port
RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
-
No. of Ports
1
-
Connector
DB9 male
-
Serial Standards
RS-232/422/485
-
Baudrate
50 bps to 921.6 kbps
-
Data Bits
7, 8
-
Parity
Even, Mark, None, Odd, Space
-
Stop Bits
1, 2
-
Flow Control
RTS Toggle (RS-232 only), RTS/CTS
-
RS-485 Data Direction Control
ADDC® (automatic data direction control)
-
Pull High/Low Resistor for RS-485
1 kilo-ohm, 150 kilo-ohms
-
Terminator for RS-485
120 ohms
-
Isolation
2 kV (built-in)
-
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
-
RS-422
Tx+, Tx-, Rx+, Rx-, GND
-
RS-485-2w
Data+, Data-, GND
-
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND
-
Industrial Protocols
Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave, IEC 60870-5-101 Master (Balanced/Unbalanced), IEC 60870-5-101 Slave (Balanced/Unbalanced)
-
Configuration Options
Serial Console
-
Mode
Master, Slave
-
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
-
Max. No. of Commands
128
-
Mode
Client (Master), Server (Slave)
-
Functions Supported
1, 2, 3, 4, 5, 6, 15, 16, 23
-
Max. No. of Client Connections
32
-
Max. No. of Server Connections
32
-
Max. No. of Commands
128
-
Mode
Client
Server -
Max. No. of Client Connections
32
-
Max. No. of Server Connections
32
-
Max. No. of Information Objects
2000 points
-
Mode
Master (Balanced/Unbalanced)
Slave (Balanced/Unbalanced) -
Max. No. of Master Connections
1
-
Max. No. of Slave Connections
1 (Balanced), 31 (Unbalanced)
-
Max. No. of Information Objects
2000 points
-
microSD Slot
Up to 32 GB (SD 2.0 compatible)
-
Input Voltage
12 to 48 VDC
-
Input Current
455 mA @ 12 VDC
-
Power Connector
Screw-fastened Euroblock terminal
-
Contact Current Rating
Resistive load: 2 A @ 30 VDC
-
Housing
Metal
-
IP Rating
IP30
-
Dimensions
36 x 105 x 140 mm (1.42 x 4.14 x 5.51 in)
-
Weight
507 g (1.12 lb)
-
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
-
Ambient Relative Humidity
5 to 95% (non-condensing)
-
Operating Temperature
MGate 5114: 0 to 60°C (32 to 140°F)
MGate 5114-T: -40 to 75°C (-40 to 167°F)
-
Safety
EN 60950-1, UL 508
-
EMC
EN 55032/24
-
EMI
CISPR 32, FCC Part 15B Class B
-
EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF -
Hazardous Locations
ATEX, Class I Division 2, IECEx Class 1 Division 2, ATEX, and IECEx certifications are underway. Please contact a Moxa sales representative for details.
-
Freefall
IEC 60068-2-32
-
Shock
IEC 60068-2-27
-
Vibration
IEC 60068-2-6, IEC 60068-2-64
-
Time
1,140,815 hrs
-
Standards
Telcordia SR332
-
Warranty Period
5 years